User Tools

Site Tools


commands:aflim

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
commands:aflim [2025/03/31 19:12] – brandoncommands:aflim [2026/08/31 17:36] (current) – tag order brandon
Line 6: Line 6:
  
 ^Shortcut |AL| ^Shortcut |AL|
-^Format  |AL [X=Log_amp_AGC] [Y=LED_intesity_pot] [Z=in_focus_mm]   |+^Format  |AFLIM [X=Log_amp_AGC] [Y=LED_intesity_pot] [Z=in_focus_mm]   |
 ^Remembered |Using SS Z | ^Remembered |Using SS Z |
  
Line 14: Line 14:
  
 ^Shortcut |AL| ^Shortcut |AL|
-^Format  |[Addr#]AL [X=Log_amp_AGC] [Y=LED_intesity_pot] [Z=in_focus_mm]   |+^Format  |[Addr#]AFLIM [X=Log_amp_AGC] [Y=LED_intesity_pot] [Z=in_focus_mm]   |
 ^Type |Card-Addressed| ^Type |Card-Addressed|
 ^Remembered |Using [Addr#]SS Z | ^Remembered |Using [Addr#]SS Z |
Line 20: Line 20:
 <-- <--
  
-**X/Y:** The X and Y arguments of this command to directly read and write values (0 to 255) to the CRISP electronics digital potentiometers.  (Not recommended for use with host software.)+**X/Y:** The X and Y arguments of this command to directly read and write values (0 to 255) to the CRISP electronics digital potentiometers.  <wrap info>Not recommended for use with host software.</wrap> 
   * See the [[:commands:lock|LK M]] command to adjust the LogAmp_AGC instead of ''AL X''.   * See the [[:commands:lock|LK M]] command to adjust the LogAmp_AGC instead of ''AL X''.
-  * See the [[:commands:unlock|UL X]] command to adjust the LED instead of ''AL Y''.+  * See the [[:commands:unlock|UL X]] command to adjust the LED intensity instead of ''AL Y''.
 \\ \\
 **Z** ''[in_focus_mm]'': The Z-argument specifies the focus precision (in millimeters) when the lock state changes from K or k to F. Useful for automatic checking of desired focus stability.  Also useful to enforce a tighter or looser focus state before indicating a lock condition.  Note that this value is overwritten whenever the NA of the objective is specified via the LR Y command as of November 2015. **Z** ''[in_focus_mm]'': The Z-argument specifies the focus precision (in millimeters) when the lock state changes from K or k to F. Useful for automatic checking of desired focus stability.  Also useful to enforce a tighter or looser focus state before indicating a lock condition.  Note that this value is overwritten whenever the NA of the objective is specified via the LR Y command as of November 2015.
Line 33: Line 34:
  
 ^Shortcut |AL| ^Shortcut |AL|
-^Format  |AL [X= x-axis highlight] [Y= y-axis highlight] [Z= safety limit enable]  |+^Format  |AFLIM [X= x-axis highlight] [Y= y-axis highlight] [Z= safety limit enable]  |
 ^Remembered |Using SS Z | ^Remembered |Using SS Z |
  
Line 41: Line 42:
  
 ^Shortcut |AL| ^Shortcut |AL|
-^Format  |[Addr#]AL [X= x-axis highlight] [Y= y-axis highlight] [Z= safety limit enable]  |+^Format  |[Addr#]AFLIM [X= x-axis highlight] [Y= y-axis highlight] [Z= safety limit enable]  |
 ^Type |Card-Addressed| ^Type |Card-Addressed|
 ^Remembered |Using [Addr#]SS Z | ^Remembered |Using [Addr#]SS Z |
Line 75: Line 76:
  
  
-{{tag>commands tiger ms2000 crisp autofocus}}+{{tag>crisp autofocus commands tiger ms2000}}
Address: 29391 W Enid Rd. Eugene, OR 97402, USA | Phone: +1 (541) 461-8181
commands/aflim.1743462766.txt.gz · Last modified: by brandon