User Tools

Site Tools


commands:here

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
commands:here [2026/09/01 14:45] – close parens brandoncommands:here [2026/09/01 15:42] (current) – add firmware requirements for clocked devices change position brandon
Line 29: Line 29:
  
 **Clocked Devices:** **Clocked Devices:**
- 
-Requires MS-2000 firmware ''9.2m'' or above, or TG-1000 firmware ''3.28'' or above. 
-On earlier firmware, ''HERE'' has no effect on clocked devices. 
  
 On clocked devices (filter slider, turret, mirrored port switch, etc), you can //change position #1// or you can //change the spacing between positions//.\\ \\ On clocked devices (filter slider, turret, mirrored port switch, etc), you can //change position #1// or you can //change the spacing between positions//.\\ \\
-Change position #1+Change position #1: <wrap lo>MS-2000 v9.2l or Tiger v3.18 required</wrap>
   - Remove all axes from either the joystick or a knob (for example, the Z-axis from the Z-knob <wrap cmd> J Z=0</wrap>).   - Remove all axes from either the joystick or a knob (for example, the Z-axis from the Z-knob <wrap cmd> J Z=0</wrap>).
   - Assign the clocked device axis to that joystick or knob (for example, the M-axis to the Z-knob <wrap cmd> J M=22</wrap>).   - Assign the clocked device axis to that joystick or knob (for example, the M-axis to the Z-knob <wrap cmd> J M=22</wrap>).
Line 40: Line 37:
   - Issue the ''HERE'' command to set the position (for example, the M-axis <wrap cmd> H M=1</wrap>).   - Issue the ''HERE'' command to set the position (for example, the M-axis <wrap cmd> H M=1</wrap>).
   - Restore (assign and unassign) the desired axes to the joystick / knobs as desired (for example, the M-axis from and the Z-axis to the Z-knob <wrap cmd> J M=0 Z=22</wrap>). \\ \\   - Restore (assign and unassign) the desired axes to the joystick / knobs as desired (for example, the M-axis from and the Z-axis to the Z-knob <wrap cmd> J M=0 Z=22</wrap>). \\ \\
-Change the spacing between positions:\\+Change the spacing between positions: <wrap lo>MS-2000 v9.2m or Tiger v3.28 required</wrap>\\
   - Move to position #2 (for example, the M-axis <wrap cmd> M M=2</wrap>).   - Move to position #2 (for example, the M-axis <wrap cmd> M M=2</wrap>).
   - Remove all axes from either the joystick or a knob (for example, the Z-axis from the Z-knob <wrap cmd> J Z=0</wrap>).   - Remove all axes from either the joystick or a knob (for example, the Z-axis from the Z-knob <wrap cmd> J Z=0</wrap>).
Address: 29391 W Enid Rd. Eugene, OR 97402, USA | Phone: +1 (541) 461-8181
commands/here.1788288342.txt.gz · Last modified: by brandon