User Tools

Site Tools


piezo_manual

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
piezo_manual [2019/04/18 19:34] – external edit 127.0.0.1piezo_manual [2026/08/31 16:33] (current) – [Disabling Strain Gauge Calibration on Startup] fix link brandon
Line 1: Line 1:
-====== ASIs Drive Electronics(ADEPT) for Piezo Top-Plate ======+====== TGADEPT & ADEPT: Drive Electronics for Piezo Top-Plate ======
  
 [{{ adept_manual_1_.jpg?direct&300 |ADEPT Card}}] [{{ adept_manual_1_.jpg?direct&300 |ADEPT Card}}]
Line 38: Line 38:
  
 ===== TTL or GPIO ===== ===== TTL or GPIO =====
-When in Internal input mode, like serial commands and manual input device, piezo stage can also be controlled with TTL. User can setup the system to move a relative distance on TTL trigger ([[commands:ttl|TTL X=2]]) or output a TTL pulse at end of commanded move ([[commands:ttl|TTL Y=2]]) etc. +When in Internal Input Mode(serial commands or a manual input device), the piezo stage can also be controlled with a TTL input. The user can setup the system to move a relative distance on TTL trigger ([[commands:ttl|TTL X=2]]) or output a TTL pulse at end of commanded move ([[commands:ttl|TTL Y=2]]). Refer to the [[commands:ttl|TTL Command]] page for more TTL input and output options. 
  
 ===== Calibration ===== ===== Calibration =====
  
 <WRAP center round info 60%> <WRAP center round info 60%>
-Note: All ADEPT boards are calibrated in the factory and undergo thorough testing. Users do not have to perform any calibration. This section is for your understanding of the piezo top-plate’s working.+Note: All ADEPT boards are calibrated in the factory and undergo thorough testing. Users do not have to perform any calibration. This section is for a better understanding of the piezo top-plate’s functionality.
 </WRAP> </WRAP>
  
Line 62: Line 62:
  
 ==== Disabling Strain Gauge Calibration on Startup ==== ==== Disabling Strain Gauge Calibration on Startup ====
- By Default every time a piezo controller is turned on , it check Strain Gauge Offset(by running the same test PZINFO does to determine if Strain Gauge offset is "OK" or "BAD"). If necessary it goes ahead and perform auto calibration routine. Changes in the sample weight, room temperature and aging require strain gauge calibration. + By Default every time a piezo controller is turned on, it checks the Strain Gauge Offset(by running the same test PZINFO does to determine if the Strain Gauge offset is "OK" or "BAD"). If necessary, it performs the auto calibration routine. **Changes in the sample weight, room temperature and piezo age require strain gauge calibration.** 
  
-If the user would like to disable this feature, issue the serial command [[commands:customa#z_o|CCA Z=15]] followed by [[commands:saveset|SS Z]]. +If the user would like to disable this feature, issue the serial command [[commands:customa#z_parameter|CCA Z=15]] followed by [[commands:saveset|SS Z]]. 
  
 ===== Fast Slow Mode ===== ===== Fast Slow Mode =====
Line 91: Line 91:
 |Piezo Travel Range (+- 5%) |150 um |300 um |500 um| |Piezo Travel Range (+- 5%) |150 um |300 um |500 um|
 |Piezo smallest move/resolution † |2.2 nm |4.5 nm |7.6 nm| |Piezo smallest move/resolution † |2.2 nm |4.5 nm |7.6 nm|
-|Maximum Load for full range travel in Kilogram |1 Kg |||+|Maximum Load for full range travel |1 Kg |||
 |Modes Capable |Fast and Slow Mode |Slow mode only || |Modes Capable |Fast and Slow Mode |Slow mode only ||
 |External Analog  input(BNC) |0 to 10 Volts ||| |External Analog  input(BNC) |0 to 10 Volts |||
  
-†This is with Piezo Drive cards’s 16Bit DAC. User may improve this thru a high resolution signal generator, and the system operating in external input mode.  +†This is with Piezo Drive cards’s 16Bit DAC. User may improve this through a high resolution signal generator, and the system operating in external input mode.  
  
 ==== Transient Response ==== ==== Transient Response ====
Line 107: Line 107:
 ==== Frequency Response ==== ==== Frequency Response ====
  
-In this test a sine wave of 2 Volt peak to peak and 5Vrms of varying frequency is applied thru external input and the response of the top-plate was interpreted on sensor out is observed and its amplitude is recorded. This is used to determine what the maximum possible input frequency is. +In this test a sine wave of 2 Volt peak to peak and 5Vrms of varying frequency is applied through external input and the response of the top-plate was interpreted on sensor out is observed and its amplitude is recorded. This is used to determine what the maximum possible input frequency is. 
  
 {{ adept_manual_1_.png?direct&300 |}}  {{ adept_manual_1_.png?direct&300 |}} 
Address: 29391 W Enid Rd. Eugene, OR 97402, USA | Phone: +1 (541) 461-8181